Home
The company
Our customers
Our products
Services
Contact us

 

CONTROL VALVES
PRESSURE REGULATORS
OTHERS VALVES

CONTOL INSTRUMENTS

ACCESSORIES



Pilots

There are mainly used to command pilot operated regulator valves, whether they are Fail to Open (VD277), or Fail to Close (RG97, RG107 and RG2050 series). The pilots have a wide adjustable range depending of the output pressure to be controlled. Their set up is made by turning an adjustment screw only.

Recommended Use: They are mainly used with clean, non viscous gaseous fluids.

Mounting: in any position.

Accessories: Hand wheel for board mounting.

P6351 Series

Used in pneumatic control to control and stabilize outlet pressure in Fail to Close failure action self operated regulator valves, such as RG97 series, RG107 series, RG2050 series, RG1197 Series or RG43 series.

Maximum Inlet Pressure: Up to 105 kg/cm 2 for P6351S series; 5 kg/cm 2 for P6351B series.

Outlet Pressure: From 0,5 kg/cm 2 up to 40 kg/cm 2 for P6351S series; from 0,02 kg/cm 2 up to 0,5 kg/cm 2 for P6351B series.

Maximum Operating Temperature: From 20 up to 65 °C .

End Connections: ¼ NPT Female threaded (according to ASME ANSI B16.11/96).

Construction Materials: Body in Carbon Steel, Stainless Steel or Aluminum; Diaphragm and Plug in Neoprene, Viton or Nylon; Spring case in Stainless Steel; Other parts in 316 Stainless Steel, Carbon Steel or Brass.

P6277 Series

Used in pneumatic control to control and stabilize outlet pressure in Fail to Open failure action self operated regulator valves, such as VD277.

Maximum Inlet Pressure: Up to 105 kg/cm 2 for P6277 series.

Outlet Pressure: From 0,5 kg/cm 2 up to 40 kg/cm 2 for P6277 series.

Maximum Operating Temperature: From 20 up to 65 °C .

End Connections: ¼ NPT Female threaded (according to ASME ANSI B16.11/96).

Construction Materials: Body in Carbon Steel or Stainless Steel; Diaphragm and Plug in Neoprene, Viton or Nylon; Spring case in Stainless Steel; Other parts in 316 Stainless Steel, Carbon Steel or Brass.

P67 Series

Used in pneumatic control to control and stabilize outlet pressure in Fail to Open failure action self operated regulator valves when P6277/PR pre reducers are used, such as VD277.

Types: P67S, P67S/2, P67B and P67B/2 are used when P6277/PR pre reducer is used.

Maximum Inlet Pressure: Up to 105 kg/cm 2 for P6277 series.

Outlet Pressure: From 0,5 kg/cm 2 up to 40 kg/cm 2 for P67S series; from 0,2 kg/cm 2 up to 0,5 kg/cm 2 for P67B series.

Maximum Operating Temperature: From 20 up to 65 °C .

End Connections: ¼ NPT Female threaded (according to ASME ANSI B16.11/96).

Construction Materials: Body in Carbon Steel or Stainless Steel; Diaphragm and Plug in Neoprene, Viton or Nylon; Spring case in Stainless Steel; Other parts in 316 Stainless Steel, Carbon Steel or Brass.



o

 


 

Types:

PR, P6351S, P6351S/AR, P6351B and P6351B/AR

 




 
Modelos:

P6277S
P6277S/2
P6277-PR
 
 

Types:

P6277S and P6277S/2 used as pilots, and P6277/PR used as pre reducer when P67S, P67S/2, P67B and P67B/2 are used.

 
Diseño web: MDM & 08ka