{"id":241,"date":"2020-05-19T23:38:30","date_gmt":"2020-05-20T02:38:30","guid":{"rendered":"http:\/\/208.71.174.164\/~eptacom\/?post_type=product&#038;p=241"},"modified":"2021-10-08T12:01:52","modified_gmt":"2021-10-08T15:01:52","slug":"rp1098","status":"publish","type":"product","link":"https:\/\/epta.com.ar\/en\/product\/rp1098\/","title":{"rendered":"RP1098"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\" wp-image-248 aligncenter\" src=\"http:\/\/208.71.174.164\/~eptacom\/wp-content\/uploads\/2020\/05\/1-1-252x300.jpg\" alt=\"\" width=\"291\" height=\"346\" srcset=\"https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/1-1-252x300.jpg 252w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/1-1-400x476.jpg 400w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/1-1.jpg 492w\" sizes=\"(max-width: 291px) 100vw, 291px\" \/><\/p>\n<p><strong>CONTROL VALVES and PNEUMATIC INSTRUMENTS<\/strong><\/p>\n<p>PRESSURE REDUCING VALVE RP1098 NORMAL CLOSE (FC)<\/p>\n<p>The EPTA\u00ae RP1098 regulating valves are used whenever sensitivity, safety and high performance are needed.<\/p>\n<p>This model of valve is usually used in gas distribution systems.<\/p>\n<p><strong>NORMAL SERVICES:<\/strong> Gas fluid.<\/p>\n<p><strong>NORMAL CHARACTERISTICS:<\/strong> Globe type body with bolted flange cover, single seat, cage set,<br \/>\nseal cage-guided, soft-seal.<\/p>\n<p><strong>STANDARD CONSTRUCTION MATERIALS:<\/strong><\/p>\n<p>Body and Flange Cover: Molten Steel<\/p>\n<p>Cage, Seal and Seat: Stainless Steel and other materials depending on the service conditions.<\/p>\n<p>Soft seat: Neoprene or PTFE<\/p>\n<p>Seal O-Ring: Neoprene<\/p>\n<p>Diaphragm Hood: Molten Steel<\/p>\n<p>Most Inner Parts: Stainless steel or other materials depending on the service conditions<\/p>\n<p>Diaphragm and Seal O-Rings: Neoprene<\/p>\n<p>&nbsp;<\/p>\n<p><strong>SIZE OF THE BODY:<\/strong> From \u00d8 \u00bd\u201d to \u00d8 4\u201d<br \/>\n<strong>MAXIMUM INLET PRESSURE:<\/strong> = 100 Kg\/cm\u00b2<br \/>\n<strong>MINIMUM \u0394p<\/strong> = 2 Kg\/cm\u00b2<br \/>\n<strong>OUTLET PRESSURE :<\/strong> From 1 Kg\/cm\u00b2 to 50 Kg\/cm\u00b2<br \/>\n<strong>TEMPERATURE RANGE:<\/strong> From -20\u00baC to 60\u00baC<br \/>\n<strong>TYPE OF CONNECTIONS:<\/strong> Thread: NPT, standard ASME B16.11\/96<br \/>\n<strong>Flanges<\/strong>: RF or RTJ \uf020# 150, # 300 or # 600, standard ASME B16.5\/96<br \/>\n<strong>DIAMETER OF THE CONTROL CONNECTIONS:<\/strong> \u00d8 \u00bc\u201d Thread NPT<br \/>\n<strong>CONTROL CHARACTERISTICS:<\/strong> Equal percentage, Linear, Quick Opening (Q-O)<br \/>\n<strong>TYPE OF INNER PARTS:<\/strong> Standard or Anti-noise<br \/>\n<strong>INSTALLATION:<\/strong> It can be installed in any position.\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 <strong>SEALING:<\/strong> Class VI, standard FCI-70-2<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-249 \" src=\"https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2.jpg\" alt=\"\" width=\"630\" height=\"185\" srcset=\"https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2.jpg 1242w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2-600x176.jpg 600w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2-300x88.jpg 300w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2-1024x300.jpg 1024w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2-768x225.jpg 768w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2-640x188.jpg 640w, https:\/\/epta.com.ar\/en\/wp-content\/uploads\/2020\/05\/2-400x117.jpg 400w\" sizes=\"(max-width: 630px) 100vw, 630px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>CONTROL VALVES and PNEUMATIC INSTRUMENTS<\/strong><\/p>\n<p>PRESSURE REDUCING VALVE RP1098 NORMAL CLOSE (FC)<\/p>\n<p>The EPTA\u00ae RP1098 regulating valves are used when it is necessary to provide sensitivity, safety and high capacity.<\/p>\n<p>This model of valve is usually used in gas distribution system.<\/p>\n<p><strong>NORMAL SERVICES:<\/strong> Gas fluids<\/p>\n","protected":false},"featured_media":2291,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[]},"product_cat":[25,34],"product_tag":[],"class_list":["post-241","product","type-product","status-publish","has-post-thumbnail","product_cat-1-valves","product_cat-blocking-system","first","instock","shipping-taxable","product-type-simple","col-xs-6 col-sm-4","col-md-4 col-lg-4","un-3-cols"],"_links":{"self":[{"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/product\/241","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/comments?post=241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/media\/2291"}],"wp:attachment":[{"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/media?parent=241"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/product_cat?post=241"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/epta.com.ar\/en\/wp-json\/wp\/v2\/product_tag?post=241"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}