VG754S
The EPTA® VG754S fail to open (FTO) pressure regulating valve has an incorporated blocking system, and the blocking seal is independent from the regulation seal. The manual reset is done using a lever, the blocking system and the automatic reset is done using pneumatic relays.
They are used when sensitivity, safety and high performance are needed in distribution networks.
- Descripción
Descripción
FEATURES | |
Models | VG754S |
Variants | VG754CS |
Diameter of the Valve | Ø1″ to Ø 8″ |
Type of Connections | Thread: NPT female standard ASME B16.11 up to Ø2”
Flanges: RF or RTJ#150, # 300, # 600, standard ASME B16.5 |
Maximum Inlet Pressure | From 27 Bar to 100 Bar; depending on the variant |
Reduced Pressure Range | From 0,020 Bar to 50 Bar depending on the variant |
Control Characteristics | Equal Percentage, Linear or Quick Opening |
Operation | With Pilot P6358S |
Fail Position | Open |
Type of Body | Globe |
Material of the Body | Molten Steel ASTM A216-WCC |
Watertightness | Class VI (standard FCI 70-2) |