VD277SA

REGULATING DIAPHRAGM VALVE  with BLOCKING SYSTEM VD277S

The EPTA® diaphragm valve with blocking system VD277S is a pressure regulator valve which is used in industries and distribution systems. The operating principle is based in the pressure difference on the diaphragm made by the regulation. It has an external regulated pilot P67S/2, an external variable restrictor RV2 and a filter F250. It has a security system with a blocking system with an independent seal.

The blocking trigger in VD277S is composed by a piston or diaphragm. The return is automatically made by the automatic relay. If it is used as a blocking active valve there is also a noise attenuator.
For the VD277SA/AR the blocking system and automatic return is commanded by two pilots (cut when high pressure and return when low pressure) which set point values are regulated.

 

 

 

Descripción

FEATURES
Models VD277SA (with automatic blocking and reset)
Variants VD277SA ; SA/AR (when required)
Diameter of Valves Ø1″ to Ø6″ (Ø8” ask sales department)
Type of Connections Thread: NPT female up to Ø 2″, standard ASME B16.11

Flange: #150 RF, # 300 RF, # 600 RF, standard ASME B16.5

Maximum Inlet Pressure 100 Kg/cm²
Reduced Pressure Range From 0,02 Kg/cm² to 50 Kg/cm² for VD277.

From 1 Kg/cm² to 50 Kg/cm² for VD277H; for reduced pressures over 51Kg/cm²  contact the manufacturer

Relief Pressure Range From 2 Kg/cm² to 15 Kg/cm², for VD277A
Control Characteristics On demand
Operation Blocking indicator micro switch

Stainless Steel Noise Attenuator.

Type of Body Globe
Material of the Body Molten steel  ASTM A216-WCC (special materials on demand)
Watertightness Class VI standard FCI 70-2
Optional Pre- Reducer